DN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater Treatment

Product Details
Customization: Available
After-sales Service: Quick Response Technical Support
Warranty: 18months
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

100% Finished Products Inspection
The supplier inspects 100% of finished products.
R&D Capabilities
The supplier has 10 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Enterprise intellectual property management system certification
Digital Management Enterprise
The supplier enhances business efficiency through digitalization, which involves:
-Implementing a digitalization process
-Developing a technical transformation plan
-Real-time monitoring of big data
-Utilizing an ERP system for digital management
-Employing an OA system to streamline processes
-Implementing a CRM system for customer relationship management
-Adopting a SAP system for internal financial management
to see all verified strength labels (26)
  • DN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater Treatment
  • DN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater Treatment
  • DN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater Treatment
  • DN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater Treatment
  • DN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater Treatment
  • DN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater Treatment
Find Similar Products
  • Overview
  • Product detailed parameters
  • Functional Features:
  • Industry Applications:
  • Product Principle:
  • Electrode material:
  • Performance Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
PMF-G-GF-PN16-65K1F1T1W67Q5410C
Accuracy
±0.2-0.5%
Main Application
Water, Wastewater
Size
DN100-500
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, ISO
Caliber Range
DN15-DN1200
Pressure Ratings
1.0 MPa, 1.6 MPa, 2.5 MPa, 4.0 MPa
Accuracy Range
0.2%~0.5%
Feature
4-20mA Output, Pulse Output, RS485 Modbus
Supply voltage
110/220VAC 100-240VAC 50Hz/60Hz 24VDC ±10
Housing material
Standard carbon steel and stainless steel are need
Transport Package
Professional and Reliable Packaging
Specification
About 22KG
Trademark
PANGU
Origin
Zhejiang
HS Code
3301969
Production Capacity
10000

Packaging & Delivery

Package Size
49.00cm * 36.00cm * 36.00cm
Package Gross Weight
22.000kg

Product Description

 

Product detailed parameters


DN65 caliber,PN16, 316L electrode,Rubber lining, carbon steel sensor, integrated high-precision electromagnetic flow meter.

PMF series electromagnetic flowmeters:
 
It is suitable for conductive media with a conductivity greater than 5uS/cm. It has a wide range of nominal diameters, and can adapt to various actual environmental conditions. It has multiple power supply methods and various signal outputs. It adopts a standard RS-485 serial communication interface, supports the internationally universal standard MODBUS-RTU communication protocol, as well as a variety of wireless and wired communication networking methods such as GPRS. It has a cumulative pulse equivalent output. A wireless meter reading system (computer management software and database) that allows remote network access is provided.
 
Functional Features:
  • Excellent measurement repeatability and linearity
  • Good reliability and anti-interference performance
  • Good pressure-resistant sealing performance
  • Measuring tube with low pressure loss
  • Highly intelligent
  • Maintenance-free
Industry Applications:

The electromagnetic flowmeter is a high-precision and high-reliability velocity-type flowmeter, which is widely used in industries such as petroleum, chemical engineering, steel, food, electric power, papermaking, water treatment, water supply, heating, and environmental protection.
 
Product Principle:

The electromagnetic flowmeter consists of two parts: the sensor and the converter. The sensor is composed of components such as the measuring tube, electrodes, excitation coils, iron core, and housing. After amplifying, processing, and calculating the flow signal, the converter can display the instantaneous flow rate and cumulative flow rate, and output signals such as pulses and analog currents, which are used for the measurement and control of fluid flow. The PMF series electromagnetic flowmeter adopts an intelligent converter, which not only has functions such as measurement and display, but also supports functions such as remote data transmission, wireless control, and alarming.
 
Electrode material:
 
Electrode is used to obtain traffic signals , which will directly contact with the measured medium , so when chooses the  electrode  material ,  the suitability  between  the electrode  material  and  measured  medium  is  needed  to  be considered , namely that the corrosion resistance of the electrode material , passivation , wear, and other factors are needed to considered.
You can choose a variety of electrode materials ( including stainless steel 316L , Hastelloy B ( HB) , Hastelloy C ( HC) , titanium (Ti) , tantalum (Ta) , platinum ( Pt) , etc . ) to accommodate different measurement medium .

The selection of electrode materials should be determined according to the corrosive property of medium , and the corrosion resistance of the electrode material can be seen in the table of electrode material corrosion resistance and use range , more detailed information can be found in the preservative manual .
Material Corrosion Resistance
Stainless steel 316L
 
Application:
1 . Domestic water, industrial water, raw water wells , urban pollution .
2 . Weak corrosive acid , alkali , salt solution .
 
Hastelloy B ( HB)
 
Application:
1 . Non-oxidizing acid ;
2 . The alkali ( part) , for example , sodium hydroxide (concentration is less than 50%) ;
3 . Acid ( part) , such as phosphoric acid , and organic acid. NA: nitric acid.
 
Hastelloy C ( HC)
 
Application:
1 . mixed acid , for example , a mixed solution of chromic acid and sulfuric acid.
2 . oxidizing salts , such as Fe3 +, Cu2 +, sea water. 
 
Titanium (Ti)
 
Application:
1 . salt (part) , for example , ( 1 ) hydrogen chloride (chloride/ magnesium/aluminum/ calcium / ammonia / iron , etc . ) ; (2 ) the sodium , potassium , ammonium , hypochlorite , sea water.
2 . The alkali ( part) , such as the potassium hydroxide , ammonium hydroxide , barium  hydroxide alkaline solution which have a less than 50% concentration .
NA: hydrochloric acid , phosphoric acid 
 
Tantalum (Ta)
 
Application:
1 strong acid , such as hydrochloric acid (concentration is less than 40%) , sulfuric acid and concentrated sulfuric acid ( not including oleum) .
2 . chlorine dioxide , ferric chloride , hypochlorous acid , sodium cyanide and lead acetate .
3 . oxidizing acids such as nitric acid ( including fuming nitric acid) and the aqua regia whose temperature is below 80 ° C.
NA: alkali 
 
Platinum ( Pt)
 
Application: 1 almost all acids , alkalis , salt solutions ( including fuming sulfuric acid , fuming nitric acid)
NA: aqua regia , ammonium salt
 
 
Performance Parameters
Executive standard JB/T 9248-2015  
Nominal diameter 15-2000mm  
Velocity range 0-10m/s  
Degree of accuracy ±0 .5% R , ±1% R(< DN20  )  
Medium conductivity 5uS/cm ,Actual conductivity30uS/cm  
Nominal pressure 1.0 ~ 4.0MPa  
Environment temperature LCD Display -10ºC ~ +55ºC
OLED Display -30ºC ~ +55ºC
Medium temperature Lining Temperature Limited
CR 0 ~ 80ºC
PTFE 0 ~ 120ºC
FEP 0 ~ 120ºC
PFA -10 ~ 180ºC
FVMQ 70 ~ 250ºC
PU -20 ~ 60ºC
Output signal 4-20mA; Pulse/ Frequency 2kHz( Default),5KHz( Max)
Cable entry size M20 × 1. 5  ( Standard nylon waterproof connector, optional explosion-proof metal connector)
Supply voltage 110/220VAC( 100-240VAC),50Hz/60Hz;24VDC ±10%
Power dissipation ≤1 5VA
Digital communication RS-485, Support standard Modbus-RTU protocol;GPRS
Signal electrode and the    ground electrode material Stainless steel 316L , Hastelloy C , Hastelloy B ,titanium , tantalum , platinum
Form of electric pole Interpolating , extrapolating electrode need to customize
Number of electrodes Standard configuration 3-4 electrodes (two measuring electrodes plus a grounding electrode ) , according to the caliber configuration
Flange Standard Conform to the international GB9119 ( customize according to customer's demand)
Connecting flange material Standard carbon steel and stainless steel are needed to be customized
Grounding ring material Stainless steel , and stainless steel that contains molybdenum , etc .
DN15-DN450 Stainless steel 1Cr18Ni9Ti( Ordinary austenitic stainless steel SUS321)
Housing material Standard carbon steel and stainless steel are needed to be customized

Level of protection
Separate body-type IP68, IP65
  Incorporate type IP65
Interval / wire length     ( Separate body-style) 10m standard configuration connecting line , optional 1 ~ 300m .

 PMF-G series electromagnetic flowmeter selection table
model                                                                  Suffix Code instructions
                         
PMF-G-                         Electromagnetic flowmeter
Flange type G                       Flange type
                 Ordinary type F                     Ordinary type
                    Pressure rating
 
PN6                   National  flange ,0 .6Mpa
PN10                   National  flange , 1 .0Mpa
PN16                   National  flange , 1 .6Mpa
PN25                   National  flange ,2 .5Mpa
PN40                   National  flange ,4 .0Mpa
J IS10K                   Japanese flange ,JIS10K
ANSI150                   American flange,ASME/ANSI150
                                   Caliber -15                 Minimum diameter( mm)
-1200                 Maximum diameter( mm)
                                                 Body material                 Carbon steel (default)
M1               Stainless steel 304
M2               Stainless steel 316L
                                             Electrode material K1             Stainless steel 316L
K2             Hastelloy C
K3             Hastelloy B
K4             Titanium
K5             Tantalum
K6             Platinum
K7             Tungsten carbide
                                                                       Lining material
 
F1           Neoprene  (CR)
F2           P46( FEP)
F21           P46( FEP) lined steel mesh
F3           Teflo
F31           Teflo lined steel mesh
F4           PTFE( F4)
F6           Polyurethane rubber
                                                                         Degree of protection W65         Ip65
W67         Ip67
W68         Ip68
                                                                                   Converter type
 
Q5410C       QX5410Incorporate type
Q5410S       QX5410Separate type
Q3400S       QX3400Separate type
Q3300S       QX3300Separate type
                                                                                            Electrical interface
 
      M20* 1 .5 (default)
/HC1     1/2NPT internal thread
/HC2     1/2NPT external thread
/HC3     G1/2 internal thread
/HC4     G1/2 external thread
/HC5     G3/4 internal thread
                                                                                        Additional Features
 
/TH1   4-20mA+HART
/EX   Explosion proof type
/P1   DC24V power supply
/CT   Bluetooth Communicator
/KD1   OLED display


Caliber optional table
Caliber DN( mm)                                                                                         Volume flowqv(m3/h)
v ( m/s) 0. 57 0.7 0.9 1. 1 1.4 1.7 2.3 2.8 3.4 4. 5 5.7 6.8 9. 1  
25 1.0 1.2 1.6 2.0 2. 5 3.0 4.0 5.0 6.0 8.0 10 12 16  
32 1.6 2.0 2. 5 3.0 4.0 5.0 6.0 8.0 10 12 16 20 25  
40 2. 5 3.0 4.0 5.0 6.0 8.0 10 12 16 20 25 30 40  
50 4.0 5.0 6.0 8.0 10 12 16 20 25 30 40 50 60  
65 6.0 8.0 10 12 16 20 25 30 40 50 60 80 100 120
80 10 12 16 20 25 30 40 50 60 80 100 120 160  
100 16 20 25 30 40 50 60 80 100 120 160 200 250  
125 25 30 40 50 60 80 100 120 160 200 250 300 400  
150 40 50 60 80 100 120 160 200 250 300 400 500 600  
200 60 80 100 120 160 200 250 300 400 500 600 800 1000  
250 100 120 160 200 250 300 400 500 600 800 1000 1200    
300 160 200 250 300 400 500 600 800 1000 1200 1600 2000    
350 200 250 300 400 500 600 800 1000 1200 1600 2000 2500    
400 250 300 400 500 600 800 1000 1200 1600 2000 2500 3000    
450 300 400 500 600 800 1000 1200 1600 2000 2500 3000      
 
Detailed Photos


 material
trode materia


DN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater Treatment


DN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentDN65 High Accuracy 0.2% Magnetic Flow Meter with IP67 for Wastewater TreatmentQ1: Could I visit your factory?
Sincerely invite you to visit our factory,Our factory and office are all in Hangzhou,Zhejiang.
Q2: Do you provide samples?
Yes,we have materials in stock to help you to get the samples as soon as we can.
Q3: How about the quality of the managements?
We have a complete quality control system , all of our products will be fully pre-inspection by QC departments before shipping to you . We have the certification of ISO,CE we could send the certification test of our company to you.
Q4: What is your payment method?
30% prepayment, 70% before shipment.
Q5: What is the warranty for your product? 
Warranty: 18 months, Lifetime maintenance.
Q6: How soon can you arrange the production?
Once getting your product confirmation and receiving your payment, we will arrange the production immediately. For some products we have it in stock.
Q7: Could you provide me the shortest lead time?
For somre standard products we have it in stock . Pls tell me your detailed requirements, we will send to you as early as we can.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now