DN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater Treatment

Product Details
Customization: Available
After-sales Service: Quick Response Technical Support
Warranty: 18months
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
Quality Assurance
The supplier provides quality assurance
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (26)
  • DN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater Treatment
  • DN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater Treatment
  • DN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater Treatment
  • DN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater Treatment
  • DN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater Treatment
  • DN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater Treatment
Find Similar Products

Basic Info.

Model NO.
PMF-G-GF-PN40-50K1F4T1W67Q5410C
Accuracy
±0.2-0.5%
Main Application
Water, Wastewater
Size
DN10-50
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, ISO
Caliber Range
DN15-DN1200
Pressure Ratings
1.0 MPa, 1.6 MPa, 2.5 MPa, 4.0 MPa
Accuracy Range
0.2%~0.5%
Feature
4-20mA Output, Pulse Output, RS485 Modbus
Transport Package
Professional and Reliable Packaging
Specification
About 18KG
Trademark
PANGU
Origin
Zhejiang
HS Code
3301969
Production Capacity
10000

Product Description

Product detailed parameters

Electromagnetic flow meter. DN50 caliber,4.0Mpa, 316L electrode, PTFE  lining, carbon steel sensor, integrated high-precision

PMF series  flow meters:
 
It is suitable for conductive media with a conductivity greater than 5uS/cm. It has a wide range of nominal diameters, and can adapt to various actual environmental conditions. It has multiple power supply methods and various signal outputs. It adopts a standard RS-485 serial communication interface, supports the internationally universal standard MODBUS-RTU communication protocol, as well as a variety of wireless and wired communication networking methods such as GPRS. It has a cumulative pulse equivalent output. A wireless meter reading system (computer management software and database) that allows remote network access is provided.

Functional Features:
  • Excellent measurement repeatability and linearity
  • Good reliability and anti-interference performance
  • Good pressure-resistant sealing performance
  • Measuring tube with low pressure loss
  • Highly intelligent
  • Maintenance-free
Industry Applications:

The electromagnetic flowmeter is a high-precision and high-reliability velocity-type flowmeter, which is widely used in industries such as petroleum, chemical engineering, steel, food, electric power, papermaking, water treatment, water supply, heating, and environmental protection.

Product Principle:

The electromagnetic flowmeter consists of two parts: the sensor and the converter. The sensor is composed of components such as the measuring tube, electrodes, excitation coils, iron core, and housing. After amplifying, processing, and calculating the flow signal, the converter can display the instantaneous flow rate and cumulative flow rate, and output signals such as pulses and analog currents, which are used for the measurement and control of fluid flow. The PMF series electromagnetic flowmeter adopts an intelligent converter, which not only has functions such as measurement and display, but also supports functions such as remote data transmission, wireless control, and alarming.
 
Electrode material:
 
Electrode is used to obtain traffic signals , which will directly contact with the measured medium , so when chooses the  electrode  material ,  the suitability  between  the electrode  material  and  measured  medium  is  needed  to  be considered , namely that the corrosion resistance of the electrode material , passivation , wear, and other factors are needed to considered.
You can choose a variety of electrode materials ( including stainless steel 316L , Hastelloy B ( HB) , Hastelloy C ( HC) , titanium (Ti) , tantalum (Ta) , platinum ( Pt) , etc . ) to accommodate different measurement medium .

The selection of electrode materials should be determined according to the corrosive property of medium , and the corrosion resistance of the electrode material can be seen in the table of electrode material corrosion resistance and use range , more detailed information can be found in the preservative manual .
Material Corrosion Resistance
Stainless steel 316L
 
Application:
1 . Domestic water, industrial water, raw water wells , urban pollution .
2 . Weak corrosive acid , alkali , salt solution .
 
Hastelloy B ( HB)
 
Application:
1 . Non-oxidizing acid ;
2 . The alkali ( part) , for example , sodium hydroxide (concentration is less than 50%) ;
3 . Acid ( part) , such as phosphoric acid , and organic acid. NA: nitric acid.
 
Hastelloy C ( HC)
 
Application:
1 . mixed acid , for example , a mixed solution of chromic acid and sulfuric acid.
2 . oxidizing salts , such as Fe3 +, Cu2 +, sea water. 
 
Titanium (Ti)
 
Application:
1 . salt (part) , for example , ( 1 ) hydrogen chloride (chloride/ magnesium/aluminum/ calcium / ammonia / iron , etc . ) ; (2 ) the sodium , potassium , ammonium , hypochlorite , sea water.
2 . The alkali ( part) , such as the potassium hydroxide , ammonium hydroxide , barium  hydroxide alkaline solution which have a less than 50% concentration .
NA: hydrochloric acid , phosphoric acid 
 
Tantalum (Ta)
 
Application:
1 strong acid , such as hydrochloric acid (concentration is less than 40%) , sulfuric acid and concentrated sulfuric acid ( not including oleum) .
2 . chlorine dioxide , ferric chloride , hypochlorous acid , sodium cyanide and lead acetate .
3 . oxidizing acids such as nitric acid ( including fuming nitric acid) and the aqua regia whose temperature is below 80 ° C.
NA: alkali 
 
Platinum ( Pt)
 
Application: 1 almost all acids , alkalis , salt solutions ( including fuming sulfuric acid , fuming nitric acid)
NA: aqua regia , ammonium salt
 

PMF series electromagnetic flowmeter output signals are 4-20mA , RS-485 , Frequency/ Pulse . Users need to select the output signal according to the actual situation and ancillary equipment .


DN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentcElectrode material
trode materia


DN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater Treatment


DN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater TreatmentDN50 High Accuracy 0.5% Magnetic flow meter with IP67 for Wastewater Treatment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier