High-precision split-type electromagnetic flow meter DN200 caliber

Product Details
Customization: Available
After-sales Service: 18 Months
Warranty: 18 Months
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

100% Finished Products Inspection
The supplier inspects 100% of finished products.
Quality Assurance
The supplier provides quality assurance
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
Raw-Materials Traceability
The supplier has traceability identification of raw materials
to see all verified strength labels (26)
  • High-precision split-type electromagnetic flow meter DN200 caliber
  • High-precision split-type electromagnetic flow meter DN200 caliber
  • High-precision split-type electromagnetic flow meter DN200 caliber
  • High-precision split-type electromagnetic flow meter DN200 caliber
  • High-precision split-type electromagnetic flow meter DN200 caliber
  • High-precision split-type electromagnetic flow meter DN200 caliber
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • electromagnetic flowmeters:
  • Functional Features:
  • Industry Applications:
  • Product Principle:
  • Performance Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
PMF-G-GF-PN10-200K1F1T1W68Q3410S
Accuracy
±0.2-0.5%
Main Application
Water, Wastewater
Size
DN100-500
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, CE, ISO
Caliber Range
DN15-DN1200
Nominal Pressure
1.0 MPa, 1.6 MPa, 2.5 MPa, 4.0 MPa
Power Supply
110V~220V, 24V, Battery
Signal Output
4-20mA, Pulse, RS485
Probe
316L, Ti, Ta
Transport Package
Cartons and Wooden Box
Specification
DN10-DN500
Trademark
PANGU
Origin
Zhejiang
HS Code
3301969
Production Capacity
10000

Product Description

Product Description

Pangu DN2000 size Precision Split Flange Electromagnetic flow meter for Accurate Liquid Sewage Water
Accepting OEM factory multilingual flow meter customization.

Company Profile

Hangzhou Pangu Automation System Co., Ltd. is a national high-tech enterprise, has been focusing on the electromagnetic flow meter,electromagneticenergy meter, electromagnetic water meter design, manufacturing. 
After
 20 years of accumulation, the company has a professional and efficient R & D, manufacturing team, is one of the influential companies in the field of domestic industrial automation.The company has dozens of products related patents. 
Products have been widely used in petroleum, chemical industry, electric power, thermal power, metallurgy, building materials, food, pharmaceutical, environmental protection and municipal and other industries.

Hangzhou Pangu has been committed to providing customers with excellent products, so that Pangu manufactured products become synonymous with high quality.

electromagnetic flowmeters:
 
It is suitable for conductive media with a conductivity greater than 5uS/cm. It has a wide range of nominal diameters, and can adapt to various actual environmental conditions. It has multiple power supply methods and various signal outputs. It adopts a standard RS-485 serial communication interface, supports the internationally universal standard MODBUS-RTU communication protocol, as well as a variety of wireless and wired communication networking methods such as GPRS. It has a cumulative pulse equivalent output. A wireless meter reading system (computer management software and database) that allows remote network access is provided.
Functional Features:
  • Excellent measurement repeatability and linearity
  • Good reliability and anti-interference performance
  • Good pressure-resistant sealing performance
  • Measuring tube with low pressure loss
  • Highly intelligent
  • Maintenance-free
Industry Applications:

The electromagnetic flowmeter is a high-precision and high-reliability velocity-type flowmeter, which is widely used in industries such as petroleum, chemical engineering, steel, food, electric power, papermaking, water treatment, water supply, heating, and environmental protection.
Product Principle:
The electromagnetic flowmeter consists of two parts: the sensor and the converter. The sensor is composed of components such as the measuring tube, electrodes, excitation coils, iron core, and housing. After amplifying, processing, and calculating the flow signal, the converter can display the instantaneous flow rate and cumulative flow rate, and output signals such as pulses and analog currents, which are used for the measurement and control of fluid flow. The PMF series electromagnetic flowmeter adopts an intelligent converter, which not only has functions such as measurement and display, but also supports functions such as remote data transmission, wireless control, and alarming.
The corrosion resistance and the use range table of the electrode materia
Material Corrosion Resistance
Stainless steel 316L
 
Application:
1 . Domestic water, industrial water, raw water wells , urban pollution .
2 . Weak corrosive acid , alkali , salt solution .
 
Hastelloy B ( HB)
 
Application:
1 . Non-oxidizing acid ;
2 . The alkali ( part) , for example , sodium hydroxide (concentration is less than 50%) ;
3 . Acid ( part) , such as phosphoric acid , and organic acid. NA: nitric acid.
 
Hastelloy C ( HC)
 
Application:
1 . mixed acid , for example , a mixed solution of chromic acid and sulfuric acid.
2 . oxidizing salts , such as Fe3 +, Cu2 +, sea water. 
 
Titanium (Ti)
 
Application:
1 . salt (part) , for example , ( 1 ) hydrogen chloride (chloride/ magnesium/aluminum/ calcium / ammonia / iron , etc . ) ; (2 ) the sodium , potassium , ammonium , hypochlorite , sea water.
2 . The alkali ( part) , such as the potassium hydroxide , ammonium hydroxide , barium  hydroxide alkaline solution which have a less than 50% concentration .
NA: hydrochloric acid , phosphoric acid 
 
Tantalum (Ta)
 
Application:
1 strong acid , such as hydrochloric acid (concentration is less than 40%) , sulfuric acid and concentrated sulfuric acid ( not including oleum) .
2 . chlorine dioxide , ferric chloride , hypochlorous acid , sodium cyanide and lead acetate .
3 . oxidizing acids such as nitric acid ( including fuming nitric acid) and the aqua regia whose temperature is below 80 ° C.
NA: alkali 
 
Platinum ( Pt)
 
Application: 1 almost all acids , alkalis , salt solutions ( including fuming sulfuric acid , fuming nitric acid)
NA: aqua regia , ammonium salt
 
Performance Parameters
Executive standard JB/T 9248-2015  
Nominal diameter 15-2000mm  
Velocity range 0-10m/s  
Degree of accuracy ±0 .5% R , ±1% R(< DN20  )  
Medium conductivity 5uS/cm ,Actual conductivity30uS/cm  
Nominal pressure 1.0 ~ 4.0MPa  
Environment temperature LCD Display -10ºC ~ +55ºC
OLED Display -30ºC ~ +55ºC
Medium temperature Lining Temperature Limited
CR 0 ~ 80ºC
PTFE 0 ~ 120ºC
FEP 0 ~ 120ºC
PFA -10 ~ 180ºC
FVMQ 70 ~ 250ºC
PU -20 ~ 60ºC
Output signal 4-20mA; Pulse/ Frequency 2kHz( Default),5KHz( Max)
Cable entry size M20 × 1. 5  ( Standard nylon waterproof connector, optional explosion-proof metal connector)
Supply voltage 110/220VAC( 100-240VAC),50Hz/60Hz;24VDC ±10%
Power dissipation ≤1 5VA
Digital communication RS-485, Support standard Modbus-RTU protocol;GPRS
Signal electrode and the    ground electrode material Stainless steel 316L , Hastelloy C , Hastelloy B ,titanium , tantalum , platinum
Form of electric pole Interpolating , extrapolating electrode need to customize
Number of electrodes Standard configuration 3-4 electrodes (two measuring electrodes plus a grounding electrode ) , according to the caliber configuration
Flange Standard Conform to the international GB9119 ( customize according to customer's demand)
Connecting flange material Standard carbon steel and stainless steel are needed to be customized
Grounding ring material Stainless steel , and stainless steel that contains molybdenum , etc .
DN15-DN450 Stainless steel 1Cr18Ni9Ti( Ordinary austenitic stainless steel SUS321)
Housing material Standard carbon steel and stainless steel are needed to be customized

Level of protection
Separate body-type IP68, IP65
  Incorporate type IP65
Interval / wire length     ( Separate body-style) 10m standard configuration connecting line , optional 1 ~ 300m .
 PMF-G series electromagnetic flowmeter selection table
model                                                                  Suffix Code instructions
                         
PMF-G-                         Electromagnetic flowmeter
Flange type G                       Flange type
                 Ordinary type F                     Ordinary type
                    Pressure rating
 
PN6                   National  flange ,0 .6Mpa
PN10                   National  flange , 1 .0Mpa
PN16                   National  flange , 1 .6Mpa
PN25                   National  flange ,2 .5Mpa
PN40                   National  flange ,4 .0Mpa
J IS10K                   Japanese flange ,JIS10K
ANSI150                   American flange,ASME/ANSI150
                                   Caliber -15                 Minimum diameter( mm)
-1200                 Maximum diameter( mm)
                                                 Body material                 Carbon steel (default)
M1               Stainless steel 304
M2               Stainless steel 316L
                                             Electrode material K1             Stainless steel 316L
K2             Hastelloy C
K3             Hastelloy B
K4             Titanium
K5             Tantalum
K6             Platinum
K7             Tungsten carbide
                                                                       Lining material
 
F1           Neoprene  (CR)
F2           P46( FEP)
F21           P46( FEP) lined steel mesh
F3           Teflo
F31           Teflo lined steel mesh
F4           PTFE( F4)
F6           Polyurethane rubber
                                                                         Degree of protection W65         Ip65
W67         Ip67
W68         Ip68
                                                                                   Converter type
 
Q5410C       QX5410Incorporate type
Q5410S       QX5410Separate type
Q3400S       QX3400Separate type
Q3300S       QX3300Separate type
                                                                                            Electrical interface
 
      M20* 1 .5 (default)
/HC1     1/2NPT internal thread
/HC2     1/2NPT external thread
/HC3     G1/2 internal thread
/HC4     G1/2 external thread
/HC5     G3/4 internal thread
                                                                                        Additional Features
 
/TH1   4-20mA+HART
/EX   Explosion proof type
/P1   DC24V power supply
/CT   Bluetooth Communicator
/KD1   OLED display

Caliber optional table
Caliber DN( mm)                                                                                         Volume flowqv(m3/h)
v ( m/s) 0. 57 0.7 0.9 1. 1 1.4 1.7 2.3 2.8 3.4 4. 5 5.7 6.8 9. 1  
25 1.0 1.2 1.6 2.0 2. 5 3.0 4.0 5.0 6.0 8.0 10 12 16  
32 1.6 2.0 2. 5 3.0 4.0 5.0 6.0 8.0 10 12 16 20 25  
40 2. 5 3.0 4.0 5.0 6.0 8.0 10 12 16 20 25 30 40  
50 4.0 5.0 6.0 8.0 10 12 16 20 25 30 40 50 60  
65 6.0 8.0 10 12 16 20 25 30 40 50 60 80 100 120
80 10 12 16 20 25 30 40 50 60 80 100 120 160  
100 16 20 25 30 40 50 60 80 100 120 160 200 250  
125 25 30 40 50 60 80 100 120 160 200 250 300 400  
150 40 50 60 80 100 120 160 200 250 300 400 500 600  
200 60 80 100 120 160 200 250 300 400 500 600 800 1000  
250 100 120 160 200 250 300 400 500 600 800 1000 1200    
300 160 200 250 300 400 500 600 800 1000 1200 1600 2000    
350 200 250 300 400 500 600 800 1000 1200 1600 2000 2500    
400 250 300 400 500 600 800 1000 1200 1600 2000 2500 3000    
450 300 400 500 600 800 1000 1200 1600 2000 2500 3000      
Detailed Photos
High-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliber
High-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliberHigh-precision split-type electromagnetic flow meter DN200 caliber

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier